Xephilio OCT-A1

Taking OCTA to the next level

Canon’s Xephilio OCT-A1 provides outstanding performance and exceptional ease of use. Superior image quality and a host of automated features optimize and simplify clinical examinations, while the system’s fast scanning speed enables short examination times, improving procedure efficiency and patients’ comfort.

Key Features

Features

Fast and Easy Acquisition with Incredible Detail

Fast and Easy Acquisition with Incredible Detail

With a digital resolution of up to 1.6μm, the system enables excellent differentiation of structures and individual layers of the retina. High scanning speed of 70,000 A-scans/s enables very short examination times of usually about two seconds, resulting in less motion artefacts and increased patient comfort.

Flow Fusion Technology and Deep Learning Technology Intelligent Denoise

Flow Fusion Technology and Deep Learning Technology Intelligent Denoise

Flow Fusion and the new AI-based Intelligent Denoise option can further improve the clinical outcomes of OCTA studies. These tools greatly enhance workflow and diagnostic confidence, providing excellent patient comfort and well-being.

Angio Expert HD Software

Angio Expert HD Software

Angio Expert HD not only offers a wide range of advanced image quality tools, but also adds advanced OCTA analysis to the imaging portfolio. Angio Expert HD provides high pixel density and extended field of view, enabling the imaging of vessels and capillaries over a large area with high precision.

Clinical Cases

Going beyond the surface
With the Canon OCT-A1 the individual layers of the retina can be clearly defined.
Going beyond the surface
61-year-old male patient with recently diagnosed type 2 diabetes. Visual acuity was reduced to 0.32 in the right eye as compared to 1.0 in the left eye. On the scan, a small intraretinal accumulation of fluid can be seen to the right of the fovea. White dots in the fluid accumulation are hard exudates.
Going beyond the surface
78-year-old female patient. Accumulation of a solid material is seen in the subretinal space, RPE. The condition is a genetic macular dystrophy characterized by mild visual impairment and metamorphosia. Typical age of onset is between the fourth and sixth decade. It may progress to choroidal neovascularization and atrophy. A typical finding is attachment of the posterior hyaloid to the macular region, presumably secondary to the macular dystrophy.
Going beyond the surface
87-year-old female patient. A macular hole affects all retinal layers. The intraretinal edema at the edges of the hole is a very typical finding. Furthermore, a slight elevation of the retina is seen. There is no loss of retinal tissue, but because of intrinsic pulling forces, the edges of the hole have been pulled away from each other. Treatment is surgery with vitrectomy, inner limiting membrane peeling and injection of air or gas.
Going beyond the surface
61-year-old male patient with sudden onset of metamorphopsia. OCT imaging shows a pigment epithelial detachment (PED) just temporal to the fovea, with subretinal fluid on the shoulders of the PED. Fluorescein angiography revealed increasing hyperfluorescence in the later phases, in accordance with the presence of an occult choroidal neovascular membrane, treatment with ranibizumab was initiated.
Going beyond the surface
75-year-old female patient has reading difficulties and problems with judging distances. A pronounced thickening of the central retina can be seen (466μm). The retinal surface is wrinkled due to the fibrosis and shrinking of the membrane. Treatment is vitrectomy and inner limiting membrane peeling.
Going beyond the surface
74-year-old male patient, experiences a gradually expanding grey area in his left central vision. He is known to have a pigment epithelial detachment in his left eye. On this scan, the pre-existing pigment epithelial detachment (PED) is seen. However, overlying the PED, a cystoid macular edema caused by a venous thrombosis is evident.
Going beyond the surface
31-year-old female patient, pregnant in third trimester, suddenly experienced a blurred spot in her central vison. On OCT, an accumulation of fluid is seen under the retina in the space between the photoreceptors and the retinal pigment epithelium (RPE). However, within that same area a small detachment of the RPE can be seen as well, and an adjacent small fluid accumulation is seen to the left. There is no treatment, and the condition usually resolves spontaneously over 3-6 months. Observation and reassurance.

Specifications

Xephilio OCT-A1
Download Brochure

Specifications

Xephilio OCT-A1
Download Brochure

Specifications

Scan Rate

70,000 A-scan/second

Axial Resolution (Digital/Optical)

1.6/3μm

Transversal Resolution

20μm

Wavelength

SLD: 855nm, SLO: 780nm*1

Minimum Pupil Diameter

3.0mm

Working Distance

35mm

Fundus Imaging Method

Flying spot SLO

SLO Size (H x V)

13mm x 10mm

OCT Width

3~13mm

OCT Depth

2.0mm

Internal Fixation Light

1 x 1mm or 6 x 6mm

External Fixation Light

EL-1 (option)

Dimension and Weight

Dimension (W x D x H)

387 x 499 x 474mm

Weight

29kg

OCT Scan Parameters

Retina Scan Mode

Vitreous and choroidal modes available C-gate direction: normal/inverse
Imaging position (fixation light position) Macular/Disc/Posterior

Macula 3D

1024 A-scan x 128 (10 x 10mm) Horizontal

Glaucoma 3D

1024 A-scan x 128 (10 x 10mm) Vertical

Disc 3D

512 A-scan x 256 (6 x 6mm) Horizontal

Custom 3D

1024 A-scan x 128 Vertical/Horizontal
3x3mm/6x6mm /10x10mm

Multi Cross

1024 A-scan (horizontal 3 – 13mm, vertical 3 – 10mm)
Averaging: 1 – 50

Cross

1024 A-scan (horizontal 3 – 13mm, vertical 3 – 10mm)
Averaging: 1 – 200

Radial

1024 A-scan (3mm/6mm/10mm)
12 directions (15-degree interval)
Averaging: 1 – 50

OCTA

OCT angiography

Anterior Scan Mode (Option)

C-gate direction: Normal
Imaging position: Center of SLO

Anterior 3D

6mm Horizontal

Anterior Cross

3mm/6mm Horizontal
Averaging: 1– 200

Anterior Radial

6mm 12 directions (15 degrees interval)

  1. Output on cornea < 1.5mW for SLD, 1.0mW for SLO (scanning beam controlled by the laser safety system)