CXDI-703C Wireless

New Pro-range cost effective digital radiography solution for everywhere in hospital

Designed to help healthcare professionals attain a high level of performance, usability, and reliability.

Key Features

Features

CXDI-703C Wireless User Friendly Design 22_fetish

User Friendly Design

Shape designed for easier positioning and round corners are comfort for patient and user. Comfortable grips to safely hold and easy to carry the product.

CXDI-703C Wireless Workflow Improvement 10_slant_v2

Workflow Improvement

Long lasting battery life more than 10 hours in standby mode. Cycle time < 5 seconds. Time for ready < 4 seconds. Preview time 1 second*.

*Depending on acquisition mode.

CXDI-703C Wireless Last Image Hold 11_rev_slant_v2

Last Image Hold

The last image is always on the detector, even when connection to the WIFI is suddenly interrupted. This provides you with the confidence that no unnecessary dose is applied to the patient.

Related Reads

Specifications

CXDI-703C Wireless
Download Brochure

Specifications

CXDI-703C Wireless
Download Brochure

Specifications*1

Purpose

General Radiography

Scintillator

Csl (Cesium Iodide)

Weight (incl. battery)

2.9 kg

Effective Imaging Area

35 x 43 cm

External Dimensions

38 x 46 cm

Image Matrix Size

2,496 x 3,040 pixels

Pixel Size

140 μm

Resolution

3.5 lp/mm

DQE

Typical 65% (0 lp/mm) / 58% (0.5 lp/mm)*2

Grey Scale

A/D: 16 bit

Preview Image Time

1 sec.*3

Cycle Time

< 5 sec.*3

Dust- and Waterproof

IP55*4

Battery Performance

Standard Synchronisation mode

Approx. 1,500 images @ 7 sec. cycle,
140 images @ 100 sec. cycle

Non-Generator Connection mode

Approx. 1,500 images @ 7 sec. cycle,
140 images @ 100 sec. cycle

Charging Performance

Detector charging in detector stand:
approx. 150 min.*5
In battery charger: approx. 150 min.*5

Wireless Channel/Band

2.4 GHz, 5 GHz (W52, W53, W56, W58)*6

  1. Specifications subject to change.
  2. 0 lp/mm is extrapolated value IEC62220-1-1 2015 (RQA5).
  3. Dependent on acquisition mode.
  4. Based on tests conducted by an independent institution. Certification does not guarantee against failure or damage. Dust and water resistance may be compromised by substantial impacts (dropping, crushing, etc.).
  5. At an ambient temperature of 25°C.
  6. W53, W56 supports only in module receiver mode.

Product Disclaimer

  • 01. Please refer to individual country / region websites and respective sales offices for product availability.
  • 02. Specifications, availability and terms of offers may change without notice.
  • 03. Products / Services may be manufactured by and/or supplied to us by third party manufacturers / suppliers for distribution / resale (non-Canon brand products).